Zobrazit minimální záznam

dc.contributor.advisorBerger, Josef
dc.contributor.authorTrefilová, Terezie
dc.date.accessioned2021-12-03T08:52:01Z
dc.date.available2021-12-03T08:52:01Z
dc.date.issued2009
dc.date.submitted2009-08-17
dc.identifier.urihttps://dspace.jcu.cz/handle/20.500.14390/18337
dc.description.abstractABSTRAKT: Naše práce studovala morfologii hemocytů a stabilitu základních nepatologických hematologických hodnot v průběhu 24 hodin, jako biomodel byla použita Spodoptera littoralis. (Boisd.) (Lepidoptera: Noctuidae) v šestém instaru. K pozorování hemocytů jsme vybrali světelnou mikroskopii. Před vlastním pozorováním jsme z odebrané hemolymfy zhotovili preparát, který jsme obarvili pomocí Pappenheimova barvení. Tato metoda barvení se běžně používá ve veterinární i v humánní laboratorní praxi v hematologii. Pozorovali jsme 6 druhů hemocytů a to: malé granulocyty (mGR), velké granulocyty (vGR), malé prohemocyty (mPR), velké prohemocyty (vPR), sférulocyty (SF) a plazmatocyty (PL). Pappenheimovo barvení nám též umožnilo pozorovat apoptózu. Znalost cirkadiánních změn hemocytů u S. littoralis, je velice důležitý fakt, pakliže bychom chtěli využívat tohoto živočicha jako nový biomodel například pro výzkum v oblasti imunologie, hematotoxikologie nebo farmakotoxikologie. Změny v hladinách některých látek mohou být fyziologické a to, i když jsou mimo hranici referenčních hodnot (Knapp et al., 1984). Zjistili jsme, že počet jednotlivých hemocytů v průběhu dne není stálý. O půlnoci pozorujeme nejnižší počet mPR i vPR a naopak nejvyšší počet apoptotických buněk a vGR. Pro zpřesnění a zrychlení odečtu koncentrace, jsme zkusili využít přístroje ELISA reader (Sunrise, Tecan) založený na fotometrickém měření. Vzhledem k velkým rozsahům naměřené koncentace (cca. od 2-30 mmol/l) posuzujeme využití ELISA readeru jako nevhodné.cze
dc.format47
dc.format47
dc.language.isocze
dc.publisherJihočeská univerzitacze
dc.rightsBez omezení
dc.subjectApoptózacze
dc.subjectDiferenciální rozpočet hemocytů (DHC)cze
dc.subjectHemocytycze
dc.subjectKoncentrace hemocytůcze
dc.subjectPappenheimovo barvenícze
dc.subjectSpodoptera littoralis (Boisd.)cze
dc.subjectApoptosiseng
dc.subjectDifferential hemocyte count (DHC)eng
dc.subjectHemocyteseng
dc.subjectConcentration hemocyteseng
dc.subjectPappenheim stainingeng
dc.subjectSpodoptera littoralis (Boisd.)eng
dc.titleCirkadiánní změny hemocytů Spodoptera littoraliscze
dc.title.alternativeCircadian changes of Spodoptera littoralis haemocyteseng
dc.typebakalářská prácecze
dc.identifier.stag12956
dc.description.abstract-translatedAbstrakt This work is a study of the morphology of hemocytes and stability of the basic non-pathological hematological levels during 24 hours. Spodoptera littoralis. (Boisd.) (Lepidoptera: Noctuidae) in the sixth instar was used as the biological model. Light microscopy was the technique used to observe the hemocytes. Prior to the microscopy, preparations were made from the hemolymph and stained by Pappenheim's staining method. This is a method which is routinely used in veterinary as well as human laboratory practice in hematology. Six types of hemocytes were observed: small granulocytes (sGR), large granulocytes (lGR), small prohemocytes (sPR), large prohemocytes (lPR), spherulocytes (SP), and plasmatocytes (PL). Pappenheim's staining also enabled apoptosis to be followed. The knowledge of circadian changes in hemocytes in S. littoralis is very important if this animal is to be employed as a new biological model, for instance, for investigations in imunology, hematotoxicology or pharmacotoxicology. Changes in the levels of some substances can be physiological even if lying beyond the reference level limits (Knapp et al., 1984). We found the various hemocyte counts varying throughout the day. At midnight, the sPR and lPR counts are lowest while the apoptotic cell and lGR counts are highest. We tested the use of an ELISA reader (Sunrise, Tecan) (which is based on the photometric principle) with a view to increasing the precision and shortening the time of analysis. However, due to the large spans of concentrations, viz. roughly from 2 mmol/l to 30 mmol/l, the use of the ELISA reader was found unsuitable.eng
dc.date.accepted2009-09-14
dc.description.departmentZdravotně sociální fakultacze
dc.thesis.degree-disciplineZdravotní laborantcze
dc.thesis.degree-grantorJihočeská univerzita. Zdravotně sociální fakultacze
dc.thesis.degree-nameBc.
dc.thesis.degree-programSpecializace ve zdravotnictvícze
dc.description.gradeDokončená práce s úspěšnou obhajoboucze
dc.contributor.refereeGelbič, Ivan
dc.description.defenceProf. RNDr. Berger: Studentka pracovala samostatně, později vázla komunikace s vedoucím práce. Zmatení v pojmu Apoptóza. Viz. Hodnocení prezentace slabší. MUDr. Verner: Bez připomínek Ing. Kašparová: Práce dobrá, prezentace slabší MUDr. Blažek (hostující): proč není žádná zmínka o Erythrocyteum? Studentka odpověděla dobře. MUDr. Horanová: Slabší prezentace RNDr. Vrajová: Proč se nehodí Elisa Leader k tomuto vyšetření? Studentka: vzorky jsem měřila proti dest. Vodě (blank). Měřila jsem zákal. Měření bylo zatíženo chybou. Prof. MUDr. Velemínský: Erytrocyt není hematocyt? Studentka odpověděla dobře. Umíte perfektně anglicky? Máte udáno 54 zahraničních autorů. Studentka: čerpala jsem z internetových stránek.cze


Soubory tohoto záznamu

Thumbnail
Thumbnail
Thumbnail

Tento záznam se objevuje v

Zobrazit minimální záznam